Vax Turbo Force V-060P Spezifikationen Seite 16

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 47
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 15
16
Lubrication procedure for all vacuum pumps on start up
(This procedure must be followed prior to the operation of a new
vacuum pump.):
With force feed lubrication type, install dripper on
top of pump and connect rubber lines.*
Remove dipstick and fill oil reservoir with
recommended turbine oil.
With 540 RPM pumps: fill gear housing to level of
clear plastic sight plug on the side of the housing
with SAE 90 gear oil.
Remove plastic cap on air inlet and pour 2 oz. turbine
oil into pump. Start pump slowly and with valve in
suction position, pour 2 oz. turbine oil into air inlet.
At this point oil should be visible in the dripper or oil
lines. Adjust dripper flow to 1 drop every 2 seconds.
*Dripper will be shipped loose or taped to the bottom
of the changeover valve handle.
Automatic oil pump
The automatic oil pumps are set at the factory
during pump testing and should require no further
adjustment during pump installation.
The pumps are adjusted to one drop every two
seconds per outlet. This oil rate equals 2.7 fluid oz.
per hour.
Seitenansicht 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 46 47

Kommentare zu diesen Handbüchern

Keine Kommentare