8.1 Connecting the Q-bus Cables
Connect the two Q-bus cables (BC04V–09) to the two Q-bus Out connectors
on your system. Those connectors should be in the last (leftmost) backplane
slot used in your system. The module containing those connectors is labeled
M9404–PA.
Figure 31: Connecting the Q-bus Cables
J1
J2
Slide Down
to Lock
Connector
Locking Device
MLO-006573
1. Feed the plug end of one of the cables under the system from the back
or side and up through the opening. Then insert the plug end into the
lower Q-bus Out connector (J1). Secure the connection by sliding the
lock down.
2. Feed the socket end of the other cable under the system from the back
or side and up through the opening. Then insert the socket end into
the upper Q-bus Out connector (J2). Secure the connection by sliding
the lock down.
50 VAX 4000 Model 200 (BA430) Installation