Chapter 2
Troubleshooting During Normal
Operation
Problems that occur during normal operation of your system may result
from a problem in the system, faulty settings, or incorrect procedures.
The following sections list problems, possible causes, and corrective actions.
If the action(s) listed do not solve the problem, call your Digital service
representative.
NOTE: In the following sections, the names of controls and indicators on
BA215 enclosures, when different from those on BA400-series enclosures, are
italicized and enclosed in parentheses.
2.1 System Problems
Problem Possible Cause Corrective Action
DC OK indicator lit; noth-
ing displays on console
terminal; LED on con-
sole module cover panel
displays E or F.
Problem with CPU. Call your Digital service representa-
tive.
System loses power; AC
Present indicator (BA215:
Power switch) not lit.
Plug loosened. Set Power switch to 0. Plug in system.
Set Power switch to 1.
No power at wall outlet. Use different wall outlet or check
circuit breaker controlling power to
wall outlet.
Power switch (BA215:
Circuit breaker) tripped.
Wait 1 minute, then set Power switch
to 1. (BA215: Set Power switch to
0, push Reset button, wait 1 minute,
and set Power switch to 1.) If
problem persists, call your Digital
service representative.
Troubleshooting During Normal Operation 2–1